Monitoring Methane in the European region (EU FP5-project Meth-MonitEUr)

Russian Federation section


Teriberka station methane measurement

Description:
The reported data are the mean of the CH4 concentrations measured in two simultaneously sampled flask, if the difference between them is less or equal to 6 ppb. Otherwise, the lower of the two measured values is taken as a daily value if it does not differ from the smoothed concentration curve for more than 2 standard deviations. Technically invalid data are excluded.

Data: [ASCII-file] [Graph]

Flag definition:
"+" - concentration difference in two simultaneously sampled flasks less then 6 ppb;
"S" - concentration difference in two simultaneously sampled flasks more then 6 ppb;
"M" - reported value is based on single flask data (one of two flasks is technically invalid).

[Back]